Filters
Manufacturer
More in this category
Relays
part#
description
manufacturer
2901504
Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via CANopen®. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided.
customer-131
Quick Quote
2905872
Bluetooth adapter with micro USB and S-PORT interface for wireless communication with the MINI Analog, MINI Analog Pro, MACX Analog, INTERFACE system gateways, and PLC logic device series.
customer-131
Quick Quote
2980678
PLC-INTERFACE, integrated solid-state relay, with screw connection, for mounting on NS 35/7,5 DIN rails, input: 24 V DC, output: 12 - 300 V DC/1 A
customer-131
Quick Quote
2900378
PLC-INTERFACE with electronic changeover contact, consisting of PLC-BPT…/21 basic terminal block with Push-in connection and integrated miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 changeover contact, input: 24 V DC, output: 3-48 V D
customer-131
Quick Quote
2980267
6.2 mm PLC basic terminal block for output functions with screw connection, without relay or solid-state relay, for mounting on DIN rail NS 35/7,5, with load return line connection (BB), 1 N/O contact, input voltage 5 V DC
customer-131
Quick Quote
2908175
PLC-INTERFACE for input functions with PLC logic, with screw connection and plug-in miniature solid-state relay, for mounting on a DIN rail, 1 N/O contact, input: 120 V AC/110 V DC
customer-131
Quick Quote
2908176
PLC-INTERFACE for input functions with PLC logic, with Push-in connection and plug-in miniature solid-state relay, for mounting on a DIN rail, 1 N/O contact, input: 230 V AC/220 V DC
customer-131
Quick Quote
2906919
Pt 100/Pt1000 temperature transducer for PLC logic logic modules (Generation 2 only), single-channel, signal type (Pt 100, Pt 1000) can be configured via DIP switch, Push-in connection
customer-131
Quick Quote
2906917
Analog input module for PLC logic logic modules (Generation 2 only), single-channel, signal type (4 ... 20 mA, 0 ... 20 mA, 0 ... 10 V, 2 ... 10 V) can be configured via DIP switch, Push-in connection
customer-131
Quick Quote
2906921
Analog output module for PLC logic logic modules (Generation 2 only), single-channel, signal type (4 ... 20 mA, 0 ... 20 mA, 0 ... 10 V, 2 ... 10 V) can be configured via DIP switch, Push-in connection
customer-131
Quick Quote
2906918
Pt 100/Pt1000 temperature transducer for PLC logic logic modules (Generation 2 only), single-channel, signal type (Pt 100, Pt 1000) can be configured via DIP switch, screw connection
customer-131
Quick Quote
2906916
Analog input module for PLC logic logic modules (Generation 2 only), single-channel, signal type (4 ... 20 mA, 0 ... 20 mA, 0 ... 10 V, 2 ... 10 V) can be configured via DIP switch, screw connection
customer-131
Quick Quote
40.51.9.024.0000
Miniature electromechanical PCB power relay - Flux proof (RTII) - Finder (40 series) - Control coil voltage 24Vdc - 1 pole (1P) - 1C/O / SPDT (Single Pole Double Throw) contact - Rated current 12A (250Vac; AC-1) / 12A (30Vdc; DC-1) - Rated switching power
customer-48
Quick Quote
2903521
Monitoring relay for monitoring single-phase currents of 0 ... 5 A AC or 0 ... 10 A AC, overcurrent/undercurrent or window, 1 changeover contact, with screw connection
customer-131
Quick Quote
2903522
Monitoring relay for monitoring single-phase currents of 0 ... 5 A AC or 0 ... 10 A AC, overcurrent/undercurrent or window, 1 changeover contact, with Push-in connection
customer-131
Quick Quote
2903526
Monitoring relay for monitoring 3-phase voltages of 400 V AC ±30%, window or window with phase sequence, 1 changeover contact, with Push-in connection
customer-131
Quick Quote
2903525
Monitoring relay for monitoring 3-phase voltages of 400 V AC ±30%, window or window with phase sequence, 1 changeover contact, with screw connection
customer-131
Quick Quote
2866103
Power modules, pluggable, for EMD-SL-..., supply voltage: 20.2...26.4 V AC
customer-131
Quick Quote
2885317
Power modules, pluggable, for EMD-FL-..., supply voltage: 425...550 V AC
customer-131
Quick Quote
2866077
Monitoring relay for monitoring phase sequence, phase failure and asymmetry, 342…457 V AC, supply from the measurement voltage, 2 changeover contacts
customer-131
Quick Quote
Items per page: