Filters
Manufacturer
Programmable Logic Controllers
part#
description
manufacturer
2734167
Digital I/O device for INTERBUS; fiber optic technology with 500 kbaud, eight inputs (24 V DC), eight outputs (24 V DC, 0.5 A), sensor/actuator connection via 5-pos. M12 female connectors, rugged metal housing, IP67 protection
customer-131
Quick Quote
2753232
INTERBUS-ST bus terminal block, 24 V DC, 9-pos., D-SUB with an additional local bus branch, 15-pos. D-SUB, IP20 protection, consisting of: Terminal part with screw connection and module electronics
customer-131
Quick Quote
2750769
INTERBUS-ST bus terminal module, 24 V DC, 9-pos., D-SUB with additional remote bus stub line, 9-pos. D-SUB, IP20 protection, consisting of: Terminal part with spring-cage connection and module electronics
customer-131
Quick Quote
2701151
INTERBUS branch terminal, version for extreme conditions, complete with accessories (connector plug and labeling field), with remote bus branch, 24 V DC
customer-131
Quick Quote
2701508
Axioline E PROFIBUS device in a metal housing with 8 IO-Link ports and 4 digital inputs, 24 V DC, M12 fast connection technology
customer-131
Quick Quote
2701519
Axioline E PROFINET device in a metal housing with 8 IO-Link ports and 4 digital inputs, 24 V DC, M12 fast connection technology
customer-131
Quick Quote
2700352
Axioline E-IO-Link/analog converter for connecting a temperature measurement resistor, M12 fast connection technology, straight version
customer-131
Quick Quote
1072838
Eight-channel IO-Link master provides convenient configuration of IO-Link devices using web-based management. Supports connectivity to PROFINET IO, MODBUS, and OPC UA. Features eight auxiliary digital inputs, redundant input power supply connections, plug
customer-131
Quick Quote
2701534
Axioline E, Digital I/O device, Ethernet, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection method: 3-conductor, Plastic housing, degree of protection: IP65/IP67
customer-131
Quick Quote
2832962
Inline, Block IO, Ethernet, RJ45 jack, Digital inputs: 32, 24 V DC, connection method: 3-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection method: 2-conductor, degree of protection: IP20, including Inline connector
customer-131
Quick Quote
2701540
Axioline E, Digital I/O device, Ethernet, M12 fast connection technology, Digital inputs: 8, 24 V DC, connection method: 4-conductor, Digital outputs: 4, 24 V DC, 2 A, connection method: 3-conductor, Metal housing, degree of protection: IP65/IP67
customer-131
Quick Quote
2701295
Axiocontrol for the direct control of Axioline I/Os. With 2 Ethernet interfaces, extended temperature range, and programming options according to IEC 61131-3. Complete with connector connector and marking field.
customer-131
Quick Quote
2701505
Axioline E, Digital input device, PROFIBUS DP, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Metal housing, degree of protection: IP65/IP67
customer-131
Quick Quote
2701518
Axioline E, Digital I/O device, PROFINET, M12 fast connection technology, Digital inputs: 8, 24 V DC, connection method: 4-conductor, Digital outputs: 4, 24 V DC, 2 A, connection method: 3-conductor, Metal housing, degree of protection: IP65/IP67
customer-131
Quick Quote
2701509
Axioline E, Digital I/O device, PROFINET, M12 fast connection technology, Digital inputs: 8, 24 V DC, connection method: 4-conductor, Digital outputs: 8, 24 V DC, 500 mA, connection method: 3-conductor, Plastic housing, degree of protection: IP65/IP67
customer-131
Quick Quote
2702289
Inline, Block IO, PROFINET, RJ45 jack, Digital inputs: 32 (16 fixed and 16 freely selectable), 24 V DC, connection method: 3-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection method: 2-conductor, PROFINET, -IRT, -MRP, -Fast Startup, degree of pr
customer-131
Quick Quote
2736741
The PROFINET bus coupler opens a local bus for up to 16 devices. Additional functions: 100 Mbps, auto negotiation, auto crossover, SNMP, TFTP, LLDP, 8 digital inputs, channel-specific diagnostics, short-circuit/overload protection, M12 fast connection tec
customer-131
Quick Quote
2701511
Axioline E, Digital I/O device, PROFINET, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection method: 3-conductor, Plastic housing, degree of protection: IP65/IP67
customer-131
Quick Quote
2701510
Axioline E, Digital input device, PROFINET, M12 fast connection technology, Digital inputs: 16, 24 V DC, connection method: 4-conductor, Plastic housing, degree of protection: IP65/IP67
customer-131
Quick Quote
2876928
Inline Controller with PROFINET interface for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with plug and labeling field.
customer-131
Quick Quote
Items per page:
Programmable Logic Controllers
General Guide & Overview
Programmable Logic Controllers (PLCs) are digital computers used in industrial organizations to control computer systems. They monitor inputs and make decisions about related outputs, making them an essential component in predictive maintenance systems. PLCs have a rich history, with the first one being developed by Dick Morley in 1968. Over the years, PLC technology has evolved, from physical relays and timers to PC-based software.
PLCs can be classified into different types, such as PLCs, PACs, SCADA, DCS, and DDC, each serving specific automation needs. They consist of key components, including inputs, outputs, CPUs, communications, and HMIs. PLCs operate through a scan cycle, continuously monitoring inputs, executing control programs, and controlling outputs.
Different programming languages, such as ladder logic, structured text, instruction list, function block diagram, and sequential function chart, are used to program PLCs. Compact and modular PLCs offer flexibility and scalability. PLC maintenance is essential for optimal performance, with tasks such as cleaning dust, replacing modules, and checking connections.
Types and Components of PLCs
Programmable Logic Controllers (PLCs) come in various types, each designed to meet specific automation needs. Two main types of PLCs are compact PLCs and modular PLCs. Compact PLCs are integrated single-unit systems with the processor, power supply, and I/O modules all housed together. They are ideal for smaller applications due to their smaller physical footprint. On the other hand, modular PLCs offer flexibility and scalability, allowing for easier system expansion. They are often preferred by larger or growing companies that require more extensive control.
A PLC consists of several critical components that work together to perform its function. These components include inputs, outputs, CPUs, and communication capabilities. Inputs are connected to sensors and devices to gather data and information. The gathered data is then processed by the CPU, the brain of the PLC, which evaluates and makes decisions based on the input. The output devices, connected to outputs, control various components such as valves and motors to execute the desired actions.
PLCs also have communication capabilities, enabling integration with other devices and systems in the industrial environment. This ensures seamless coordination and interaction between different elements of the automation system. PLCs are an essential part of automation systems, providing reliable control and efficient operation across various industries.
PLC Maintenance Best Practices
Proper PLC maintenance is crucial for ensuring optimal performance and minimizing breakdowns. By following a comprehensive PLC maintenance checklist, you can keep your system running smoothly and prevent costly downtime.
Here are some important PLC maintenance tasks:
Cleaning dust from input and output devices to prevent signal interference and component failure.
Changing filters regularly to control dust accumulation and maintain proper ventilation within the PLC system.
Inspecting connections for secureness to avoid loose connections that can disrupt communication and reduce reliability.
Replacing worn-out modules to prevent malfunctions and ensure accurate processing of data and commands.
Increasing awareness of unusual activity by monitoring error logs and system performance to identify potential issues before they escalate.
Backing up PLC data regularly to protect against data loss in the event of a system failure or unexpected event.
Monitoring environmental conditions such as temperature and humidity to ensure they are within the specified operating range.
Calibrating devices periodically to maintain accurate measurements and prevent deviations that can impact system performance.
Conducting visual inspections of the PLC system to identify any physical damage, loose connections, or signs of wear and tear.
Checking LED lights for proper functionality, as they provide valuable diagnostic information.
Inspecting sensors to ensure they are clean, properly aligned, and functioning correctly, as they are critical for accurate data acquisition.
Addressing electromagnetic interference by keeping sensitive components and wiring away from sources of electromagnetic radiation.
Reviewing the proximity of equipment to identify potential interference and ensure proper positioning for efficient operation.
Keeping the PLC system up to date with recalls and upgrades to benefit from the latest software patches, enhancements, and security updates.
The frequency of maintenance tasks may vary depending on factors such as the surrounding environment, machine usage, and available maintenance staff capacity. It is recommended to perform daily tasks such as dusting and tidying, while more specific tasks can be scheduled at regular intervals or based on manufacturer recommendations.
FAQ
What is a programmable logic controller (PLC)?
A programmable logic controller (PLC) is a digital computer used in industrial organizations to control computer systems. It monitors inputs and makes decisions about related outputs, making it an essential component in predictive maintenance systems.
Who invented the first PLC?
The first PLC was developed by Dick Morley in 1968.
How do PLCs work?
PLCs operate through a scan cycle, continuously monitoring inputs, executing control programs, and controlling outputs.
What are the different types of PLCs?
PLCs can be classified into types such as PLCs, PACs, SCADA, DCS, and DDC, each serving specific automation needs.
What are the key components of a PLC?
The key components of a PLC include inputs, outputs, CPUs, communications, and HMIs.
What programming languages are used for PLCs?
Different programming languages, such as ladder logic, structured text, instruction list, function block diagram, and sequential function chart, are used to program PLCs.
What are the advantages of PLCs?
PLCs offer advantages such as flexibility, scalability, easy expansion, integration with other devices and systems, and improved processing speeds.
Where are PLCs used?
PLCs are used in various industries, including manufacturing, automation, oil and gas, energy, and transportation.
How important is PLC maintenance?
PLC maintenance is crucial for ensuring optimal performance and avoiding breakdowns. Regular tasks include cleaning dust, replacing modules, and checking connections.