BLCCO-8M12LT-4AI-VI-4DO-2A-P
BL compact™ fieldbus station for CANopen, 4 Analog Inputs for Current or Voltage and 4 Digital PNP Outputs, On-machine Compact fieldbus I/O block, CANopen slave, 10, 20, 50, 125, 250, 500, 800, or 1000 kbps, Two 5-pole M12 connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 4 digital PNP outputs, 24 VDC, Max. 2A per output (4A tota
customer-128
Quick Quote
BLCEN-8M12LT-8DI-PD-8DI-PD
BL compact™ multiprotocol fieldbus station for Industrial Ethernet, 16 Digital PNP Inputs, On-machine Compact fieldbus I/O block, EtherNet/IP™, Modbus® TCP, or PROFINET slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, Two 4-pole M12, D-coded, connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 16 digital PNP inputs,
customer-128
Quick Quote
BLCEN-4M12MT-4AI4AO-VI
BL compact™ multiprotocol fieldbus station for Industrial Ethernet, 4 Analog Inputs for Current or Voltage and 4 Analog Outputs for Voltage, On-machine Compact fieldbus I/O block, EtherNet/IP™, Modbus® TCP, or PROFINET slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, Two 4-pole M12, D-coded, connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the fi
customer-128
Quick Quote
BLCEN-1M12MT-1CNT-ENC
BL compact™ multiprotocol fieldbus station for Industrial Ethernet, Digital Counter/Encoder Interface, On-machine Compact fieldbus I/O block, EtherNet/IP™, Modbus® TCP, or PROFINET slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, Two 4-pole M12, D-coded, connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, Detection
customer-128
Quick Quote
BLCCO-16M8LT-8XSG-P-8XSG-P
BL compact™ fieldbus station for CANopen, 16 Configurable Digital PNP Channels, On-machine Compact fieldbus I/O block, CANopen slave, 10, 20, 50, 125, 250, 500, 800, or 1000 kbps, Two 5-pole M12 connectors for fieldbus connection, 2 rotary switches for node address, IP67, M8 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 16 Configurable digital PNP channels, 24 VDC, Max. 0.5A per channel, Selection of filtering ti
customer-128
Quick Quote
BLCEN-1M12MT-1RS232
BL compact™ multiprotocol fieldbus station for Industrial Ethernet, RS232 Interface, On-machine Compact fieldbus I/O block, EtherNet/IP™, Modbus® TCP, or PROFINET slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, Two 4-pole M12, D-coded, connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, Transmission of serial data
customer-128
Quick Quote
BLCEN-1M12MT-1SSI
BL compact™ multiprotocol fieldbus station for Industrial Ethernet, SSI Interface, On-machine Compact fieldbus I/O block, EtherNet/IP™, Modbus® TCP, or PROFINET slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, Two 4-pole M12, D-coded, connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, Connection of SSI encoder, Max
customer-128
Quick Quote
TBDP-L2-16DOP
Fieldbus I/O module PROFIBUS-DP, 16 Digital PNP Outputs 2 A, , 2 x M12, 5-pin, B-coded, PROFIBUS-DP-Fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, ATEX Zone 2/22, Max. 2 A per output, Output diagnostics per channel
customer-128
Quick Quote
BLCEC-4M12MT-8DI-N
BL Compact Fieldbus Station for EtherCAT, 8 Digital NPN Inputs, On-machine Compact fieldbus I/O block, EtherCAT™ slave, Integrated Ethernet Switch, Two 4-pole M12, D-coded, connectors for fieldbus connection, Auto and Fixed addressing, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 8 digital NPN inputs, 24 VDC
customer-128
Quick Quote
TBEN-S1-8DIP
Compact Multiprotocol I/O Module for Ethernet, 8 Digital PNP Inputs, Input Diagnostics per Group, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps / 100 Mbps, 2x M8, 4-pin, Ethernet fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, M8 connector, 4-pin, for power supply, ATEX Zone 2/22, Input diagnostics per group, Programmable ARGEE
customer-128
Quick Quote
TBEN-S1-8DOP
Compact Multiprotocol I/O Module for Ethernet, 8 Digital PNP 2 A Outputs, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps / 100 Mbps, 2x M8, 4-pin, Ethernet fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, 4-pin M8 male connector for power supply, Galvanically isolated voltage groups, ATEX Zone 2/22, Max. 2 A per output, Output diagnostics
customer-128
Quick Quote
TBEN-S1-4DIP-4DOP
Compact Multiprotocol I/O Module for Ethernet, 4 Digital PNP Inputs and 4 Digital PNP Outputs 2 A, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps / 100 Mbps, 2x M8, 4-pin, Ethernet fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, 4-pin M8 male connector for power supply, Galvanically isolated voltage groups, ATEX Zone 2/22, Input diagnost
customer-128
Quick Quote
TBEN-L4-16DIN
Compact Multiprotocol I/O Module for Ethernet, 16 digital NPN Inputs, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps/100 Mbps, 2 × M12, 4-pin, D-coded, Ethernet fieldbus connection, PROFINET S2 system redundancy, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, 7/8, 4-pin connectors for power supply, ATEX Zone 2/22, Input diagnostics per port, Programmable AR
customer-128
Quick Quote
TBEN-LG-16DXP
Compact multiprotocol I/O module for Ethernet, 16 Universal Digital Channels, Configurable as PNP Inputs or 2 A Outputs, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps / 100 Mbps, 2x M12, 4-pin, D-coded, Ethernet fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, 7/8 male connector for power supply, 4-pin, Galvanically isolated voltage grou
customer-128
Quick Quote
TBPN-L1-FDIO1-2IOL
Compact PROFIsafe / PROFINET Block I/O Module, Safe Digital Inputs and Outputs, Standard Universal Digital Channels, IO-Link Master Ports, , PROFINET slave, Integrated Ethernet switch, 100 Mbps supported, 2 × M12, 4-pin, D-coded Ethernet fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, 7/8, 5-pin connectors for power supply, ATEX Zone 2/22, Two secure digital SIL3-inputs, Two secure digital SIL
customer-128
Quick Quote
TBEN-S2-4AO
Compact Multiprotocol I/O Module for Ethernet, 4 Analog Outputs, Configurable as Voltage or Current, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps / 100 Mbps, 2x M8, 4-pin, Ethernet fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, 4-pin M8 male connector for power supply, Galvanically isolated voltage groups, ATEX Zone 2/22, Each channel
customer-128
Quick Quote
FGEN-OM16-4001
Compact multiprotocol I/O module for Ethernet, 16 digital outputs 2 A, , Multiprotocol I/O module for the Ethernet protocols Modbus TCP, EtherNet/IP and PROFINET, PROFINET supports Fast Startup (FSU), Ethernet/IP supports QuickConnect (QC), Integrated Ethernet switch, FDT / DTM supported, Output diagnostics per channel, Two outputs per port, 7/8", 4-pin, for power supply, Power supply, galvanically separated, Fibre-glass reinforced PA6 housing, Vibration and shock-resistant, Encapsulated module
customer-128
Quick Quote
FGEN-XSG16-4001-ST
Compact multiprotocol I/O module for Ethernet, 16 configurable digital channels, pnp inputs / outputs 2 A, Input diagnostics per port, Output diagnostics per channel, Two freely selectable digital signals per port, , 7/8", 4-pin, for power supply, Fibre-glass reinforced PA6 housing, Vibration and shock-resistant, Encapsulated module electronics, Metal connectors, Degree of protection IP67
customer-128
Quick Quote
FEN20-4DIP-4DXP-DIN
Compact IP20 Multiprotocol Ethernet I/O Station, 4 Digital PNP Inputs and 4 Configurable Digital PNP Channels, , EtherNet/IP™ Slave, Modbus TCP Slave, PROFINET Slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, 2 x RJ45 Sockets for Fieldbus Connection, Can be mounted on DIN rail, 4 digital PNP inputs, 4 configurable PNP channels, DI or DO, 24 VDC, 1 A outputs, Protection class IP20
customer-128
Quick Quote
TBCJ-D1-10SPLIT-P
Passive Module, , This block has 16 I/Os and provides both the sensor supply as well as a ground in each port. There are mirrored ports (7 + 9 and 8 + 10), all pins are internally connected so that two devices can be operated with the same wire. This module can deliver 13 combined amps., Number of I/Os: 16, 2 mirrored ports (ports 7 + 9 and ports 8 + 10), Total output current: 13A, Switching current: 13A
customer-128
Quick Quote
Items per page: