Filters
Manufacturer
IO Type
Input Type
Output Type
Network Protocol
I/O Modules
part#
description
manufacturer
TBEN-LL-16DIP
Compact multiprotocol I/O module for Ethernet, 16 Digital PNP Inputs, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps/100 Mbps, 2Â Ă—Â M12, 4-pin, D-coded, Ethernet fieldbus connection, PROFINET S2 system redundancy, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, M12, 5-pin, L-coded male connector for power supply, ATEX Zone 2/22, Input diagnostics per port, Pr
customer-128
Quick Quote
BLCDN-4M12MT-8DO-0.5A-N
BL compact™ fieldbus station for DeviceNet™, 8 Digital NPN Outputs, On-machine Compact fieldbus I/O block, DeviceNet™ slave, 125 / 250 / 500 kbps, Two 5-pole M12 connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 8 digital NPN outputs, 24 VDC, Max. 0.5A per output
customer-128
Quick Quote
TBEN-S2-2COM-4DXP
Compact Multiprotocol I/O Module for Ethernet, 2 Configurable Serial Interfaces and 4 Universal Digital Channels, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps / 100 Mbps, 2x M8, 4-pin, Ethernet fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, 4-pin M8 male connector for power supply, Galvanically isolated voltage groups, ATEX Zone 2/22,
customer-128
Quick Quote
TBIL-L4-16DXP-AUX
I/O Hub for connection of digital signals to IO-Link Master, 16 Universal Digital Channels, PNP, , Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K
customer-128
Quick Quote
BLCDN-8M12L-4AI-VI-8XSG-PD
BL compact™ fieldbus station for DeviceNet™, 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels, On-machine Compact fieldbus I/O block, DeviceNet™ slave, 125 / 250 / 500 kbps, Two 5-pole M12 connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 8 Configurable digital PNP channels, 24 VDC, Max. 0.5A per cha
customer-128
Quick Quote
FDNQ-S0404G-MM
I/O Module for DeviceNet, , 4 digital pnp inputs and 4 outputs, PNP short-circuit protected inputs, 0.5 amp short-circuit protected outputs, Fiber-glass reinforced PA6 housing, Vibration and shock-resistant, Encapsulated module electronics, Metal connectors, Degree of protection IP67
customer-128
Quick Quote
FDNL-S1204H-2034
I/O Module for DeviceNet, 12 digital pnp inputs, 4 digital outputs 2 A, , For robot applications, Robust electromechanics, High magnetic field immunity, Intelligent terminating resistor, Module-related diagnostics, Short-circuit - group signal, Removable IP20 terminal, Fibre-glass reinforced housing, Shock and vibration tested, Encapsulated module electronics, Metal connector, Degree of protection IP67
customer-128
Quick Quote
TBIL-L5-16DXP-AUX
I/O hub for connection of digital signals to IO-Link master, 16 Universal Digital Channels, PNP, , Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K
customer-128
Quick Quote
BLCDP-8M12LT-8DI-P-8DO-0.5A-P
BL compact™ fieldbus station for PROFIBUS-DP, 8 Digital PNP Inputs and 8 Digital PNP Outputs, On-machine Compact fieldbus I/O block, PROFIBUS-DP slave, 9.6 kbps … 12 Mbps, Two 5-pole M12, reverse-keyed, connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 8 digital PNP inputs, 24 VDC, 8 digital PNP outputs, 24 VDC, Max. 0.5A per out
customer-128
Quick Quote
BLCDP-4M12VMH-4DO-2A-P
BL compact™ fieldbus station for PROFIBUS-DP, 4 Digital PNP Outputs, On-machine Compact fieldbus I/O block, PROFIBUS-DP slave, 9.6 kbps … 12 Mbps, Two 5-pole M12, reverse-keyed, connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, All exposed metal is stainless steel, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 4 digital PNP outputs, 24 VDC, Max. 2A per output (8A total), Two 5-pole M12 male con
customer-128
Quick Quote
TBIL-S3-8DXP
I/O Hub for connection of digital signals to IO-Link Master, 8 Universal Digital Channels, 8 M8 ports, , Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K
customer-128
Quick Quote
TBIL-LL-16DXP-AUX
I/O hub for connection of digital signals to IO-Link master, 16 Universal Digital Channels, PNP, , Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K
customer-128
Quick Quote
FDNP-L0404G-TT
I/O Module for DeviceNet, 4 digital pnp/npn inputs, 4 digital outputs 0.5 A, , 4 digital npn/pnp inputs, and 4 digital outputs, 24 VDC 0.5 A, , Wire-break monitoring, Short-circuit monitoring, Channel-related diagnostics, One channel per connector, Separate actuator power supply, Fibre-glass reinforced PA6 housing, Vibration and shock-resistant, Encapsulated module electronics, Metal connectors, Degree of protection IP67
customer-128
Quick Quote
FGEN-OM16-4001
Compact multiprotocol I/O module for Ethernet, 16 digital outputs 2 A, , Multiprotocol I/O module for the Ethernet protocols Modbus TCP, EtherNet/IP and PROFINET, PROFINET supports Fast Startup (FSU), Ethernet/IP supports QuickConnect (QC), Integrated Ethernet switch, FDT / DTM supported, Output diagnostics per channel, Two outputs per port, 7/8", 4-pin, for power supply, Power supply, galvanically separated, Fibre-glass reinforced PA6 housing, Vibration and shock-resistant, Encapsulated module
customer-128
Quick Quote
TBIL-M1-16DXP-B
I/O hub for connection of digital signals to IO-Link master, 16 universal digital channels, PNP, , Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K
customer-128
Quick Quote
FDNL-N0800-T
I/O Module for DeviceNet, 8 digital npn inputs, , 8 digital npn inputs, , Short-circuit monitoring, Module-related diagnostics, One channel per connector, Fiber-glass reinforced PA6 housing, Vibration and shock-resistant, Encapsulated module electronics, Metal connectors, Degree of protection IP67
customer-128
Quick Quote
TBEN-L4-16DIN
Compact Multiprotocol I/O Module for Ethernet, 16 digital NPN Inputs, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps/100 Mbps, 2Â Ă—Â M12, 4-pin, D-coded, Ethernet fieldbus connection, PROFINET S2 system redundancy, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, 7/8, 4-pin connectors for power supply, ATEX Zone 2/22, Input diagnostics per port, Programmable AR
customer-128
Quick Quote
BLCEN-4M12MT-8XSG-P
BL compact™ multiprotocol fieldbus station for Industrial Ethernet, 8 Configurable Digital PNP Channels, On-machine Compact fieldbus I/O block, EtherNet/IP™, Modbus® TCP, or PROFINET slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, Two 4-pole M12, D-coded, connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 8 Config
customer-128
Quick Quote
TBEN-L4-16DOP
Compact Multiprotocol I/O Module for Ethernet, 16 Digital PNP 2-A Outputs, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps/100 Mbps, 2Â Ă—Â M12, 4-pin, D-coded, Ethernet fieldbus connection, PROFINET S2 system redundancy, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, 7/8 male connector for power supply, 4-pin, Galvanically isolated voltage groups, ATEX Zone 2/
customer-128
Quick Quote
FDN20-S0404G-0220
DeviceNet module, 4 digital PNP inputs, 4 digital PNP outputs, , DeviceNet™ slave, Screw-clamp terminal block, 5-pin, for DeviceNet™ fieldbus connection, Rotary coding switch for setting the DeviceNet™ address, Screw-clamp terminal block, 10-pin, for I/O connection, Protection class IP20
customer-128
Quick Quote
Items per page:
I/O Modules
General Guide & Overview
In the world of control systems, I/O modules play a crucial role in facilitating the seamless exchange of data between the control system and external devices. These modules come in various types and offer a wide range of functionalities to meet the specific automation needs of different industries.
Before we dive into the types and options available, let's explore the fundamental functions of I/O modules. These modules serve as the intermediaries between the control system and sensors, actuators, and other peripheral devices. They ensure efficient communication, allowing the control system to receive input signals from sensors and provide output signals to actuators for precise control and automation.
Now, let's take a closer look at the different types of I/O modules. There are digital I/O modules, analog I/O modules, and specialty I/O modules. Digital I/O modules handle binary signals, such as on/off or high/low, while analog I/O modules process continuous signals like voltage or current. Specialty I/O modules are designed for specific purposes, such as temperature sensing or motor control.
When selecting an I/O module, it's important to consider the specific requirements of your control system. Factors such as the number of I/O points, communication protocols, and compatibility with the control system should all be taken into account.
With the rapid advancement of technology, I/O modules now come with a multitude of options. These options include various communication interfaces like Ethernet, USB, or serial ports, as well as additional features such as built-in diagnostics, hot-swapping capabilities, and LED indicators for easy troubleshooting.
In the next sections, we will explore the installation and management of I/O modules, as well as delve into the supported I/O modules and their features. So, keep reading to gain a comprehensive understanding of I/O modules and how they can enhance your control systems.
Installation and Management of I/O Modules
Proper setup, installation, and management of I/O modules is essential to ensure their correct functioning and compatibility with the control system. To achieve optimal performance, follow these key steps:
I/O Module Setup
1. Identify the specific I/O module required for your system based on the desired functionality.
2. Consult the manufacturer's documentation to verify compatibility with your control system and ensure that any required software or firmware updates are performed.
3. Determine the appropriate physical location for the I/O module, considering factors such as cable lengths, environmental conditions, and accessibility for maintenance and troubleshooting.
4. Connect the I/O module to the control system using the provided cables, ensuring proper alignment and secure connections.
I/O Module Installation
1. Power off the control system and any devices connected to it.
2. Insert the I/O module into the designated slot, following the manufacturer's instructions. Take note of any specific alignment or positioning requirements.
3. Secure the I/O module in place using the provided mounting brackets, ensuring a stable and vibration-free installation.
4. Power on the control system and verify that the I/O module is detected and recognized by the system.
I/O Module Management
1. Access the control system's configuration software or interface to manage and monitor the I/O module.
2. Configure the I/O module settings, such as input/output assignments, signal range, and communication protocols, according to the system requirements.
3. Regularly check the status and health of the I/O module, monitoring for any errors, malfunctions, or communication issues.
4. Perform firmware updates and maintenance tasks as recommended by the manufacturer to ensure optimal performance and reliability.
By following these installation and management guidelines, you can ensure the proper setup, installation, and ongoing functionality of your I/O modules within your control system.
Supported I/O Modules and their Features
When it comes to control systems and automation, having the right I/O modules is crucial. These modules offer a range of features and functionalities to meet specific system requirements. Let's take a closer look at some of the supported optional I/O modules and what they bring to the table.
One important aspect to consider is the I/O module's features. Different modules offer a variety of capabilities, such as analog input/output, digital input/output, temperature input, and specialty input/output. These features ensure that the I/O module can effectively communicate with and control external devices as needed, enabling seamless integration within the control system.
In addition to features, I/O modules also come with various ports for connectivity. These ports allow for easy communication and data exchange between the module and external devices. Some common ports include Ethernet ports for network connectivity, serial ports for device communication, and USB ports for easy configuration and firmware updates.
When working with I/O modules, visual feedback is essential. That's why many modules come equipped with LEDs. These LEDs provide status indicators, such as power, communication, and module health. They offer a quick and convenient way to monitor the module's operation and ensure everything is functioning as expected.
FAQ
What are I/O modules?
I/O modules are essential components in control systems that facilitate the exchange of data between the control system and external devices.
What are the major functions of an I/O module?
The major functions of an I/O module include data exchange between the control system and external devices, data buffering, data format conversion, and error detection and reporting.
What types of I/O modules are available?
There are various types of I/O modules available, including digital I/O modules, analog I/O modules, and interrupt-driven I/O modules.
How should I set up and install I/O modules?
Proper setup and installation of I/O modules are crucial for ensuring correct functioning and compatibility with the control system. It is recommended to follow the manufacturer's instructions and guidelines for installation.
How do I manage I/O modules?
I/O module management involves tasks such as configuring settings, monitoring module performance, and troubleshooting any issues that may arise.
What are some of the supported I/O modules and their features?
Supported I/O modules offer various features and functionalities to cater to specific system requirements. Some examples include modules with different types of ports such as digital and analog inputs and outputs, and modules with LED indicators for status monitoring.