Filters
Manufacturer
More in this category
Compressed Air Preparation Units
part#
description
manufacturer
531443
pressure regulator MS6N-LR-1/2-D5-AS 4 bar maximum output pressure, with pressure gauge, lockable regulator head, direction of flow: from left to right. Size: 6, Series: MS, Actuator lock: (* Rotary knob with lock, * with accessories, lockable), Assembly
customer-12
Quick Quote
533949
service unit combination MSB4N-1/4-FRC2:J6M1 Filter/pressure regulator/lubricator combination, maximum output pressure 7 bar, 40 µm filter, with pressure gauge, lockable regulator head, plastic bowl with plastic bowl guard, fully automatic condensate drai
customer-12
Quick Quote
531868
micro filter MS6N-LFM-3/8-ARV 0.01 µm filter, plastic bowl with plastic bowl guard, fully automatic condensate drain, flow direction from left to right. Series: MS, Size: 6, Design structure: Fibre filter, Grade of filtration: 0,01 µm, Condensate drain: f
customer-12
Quick Quote
532786
activated carbon filter LFX-3/4-D-MAXI High performance filter for virtually oil-free, odourless compressed air, suitable for use in the food processing industry Size: Maxi, Series: D, Assembly position: Vertical +/- 5°, Design structure: (* Active carbon
customer-12
Quick Quote
186501
service unit FRC-1/4-D-O-MIDI-A Filter/regulator/lubricator combination, bar, 40 µm filter, with metal bowl guard. With automatic condensate drain. Without pressure gauge. Size: Midi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Ve
customer-12
Quick Quote
186518
on-off valve HEE-1/2-D-MAXI-24 Used in conjunction with service units. Design structure: Piston slide, Type of actuation: electrical, Sealing principle: soft, Exhaust-air function: not throttleable, Manual override: detenting
customer-12
Quick Quote
186049
service unit LFR-1/2-D-MAXI-KF consisting of manual on/off valve, filter regulator, distributor module and pressure switch, without socket, with mounting brackets. With manual condensate drain. Size: Maxi, Series: D, Actuator lock: Rotary knob with lock,
customer-12
Quick Quote
172957
on-off valve HEE-D-MINI-110 For service units, without threaded connection plates with FRB threaded pin Design structure: Piston slide, Type of actuation: electrical, Sealing principle: soft, Exhaust-air function: not throttleable, Manual override: detent
customer-12
Quick Quote
162716
filter regulator LFR-3/4-D-7-MAXI-A Outlet pressure max. 7 bar, with metal bowl guard and pressure gauge. With automatic condensate drain. Size: Maxi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Grade of filtration
customer-12
Quick Quote
186482
filter regulator LFR-1/4-D-O-MIDI With metal bowl guard, without pressure gauge, degree of filtration 40 µm. With manual condensate drain. Size: Midi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Grade of filtration
customer-12
Quick Quote
185800
service unit FRC-1/2-D-MIDI-KA-A consisting of filter regulator, distributor module and lubricator. With automatic condensate drain and metal bowl guard. Size: Midi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Grad
customer-12
Quick Quote
162696
filter regulator LFR-3/8-D-O-MINI-A With metal bowl guard, without pressure gauge, degree of filtration 40 µm. With automatic condensate drain. Size: Mini, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Grade of filtr
customer-12
Quick Quote
185730
service unit LFR-3/4-D-MAXI-KB-A consisting of manual on/off valve, filter regulator and distributor module, with mounting brackets. With automatic condensate drain. Size: Maxi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical
customer-12
Quick Quote
172956
on-off valve HEE-D-MINI-24 For service units, without threaded connection plates with FRB threaded pin Design structure: Piston slide, Type of actuation: electrical, Sealing principle: soft, Exhaust-air function: not throttleable, Manual override: detenti
customer-12
Quick Quote
186452
pressure regulator LR-1/4-D-O-MIDI With threaded connection plate, without pressure gauge Size: Midi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Any, Design structure: directly-controlled diaphragm regulator
customer-12
Quick Quote
186485
filter regulator LFR-1/4-D-O-MIDI-A With metal bowl guard, without pressure gauge, degree of filtration 40 µm. With automatic condensate drain. Size: Midi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Grade of filtr
customer-12
Quick Quote
162714
filter regulator LFR-1/2-D-7-MIDI-A Outlet pressure max. 7 bar, with metal bowl guard and pressure gauge. With automatic condensate drain. Size: Midi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Grade of filtration
customer-12
Quick Quote
534015
service unit combination MSB6N-1/4-FRC4:J8M1 Filter/pressure regulator/lubricator combination, maximum output pressure 7 bar, 5 µm filter, with pressure gauge, lockable regulator head, plastic bowl with plastic bowl guard, fully automatic condensate drain
customer-12
Quick Quote
534190
service unit FRC-M7-D-7-5M-MICRO-H-B Without threaded connection plate, with pressure gauge, semiautomatic condensate drain Size: Micro, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Condensate drain: semi-automatic
customer-12
Quick Quote
173675
pressure regulator LR-1-D-7-O-MAXI-NPT Without threaded connection plate, connector thread in housing, without pressure gauge Size: Maxi, Series: D, Assembly position: Any, Controller function: Output pressure constant, Operating pressure: 16 bar
customer-12
Quick Quote
Items per page:
Compressed Air Preparation Units
General Guide & Overview
Compressed air is a widely used form of energy in various industries, powering pneumatic systems and equipment. However, the air leaving the compressor is often not suitable for direct use due to impurities and incorrect pressure levels. That's where air preparation units, also known as FRL units (Filter, Regulator, Lubricator), play a crucial role.
Air preparation units are designed to condition the compressed air, ensuring optimal performance and efficiency. The FRL unit consists of three separate units that carry out different phases of conditioning: filtration, regulation, and lubrication.
Filtration is the first step, where contaminants such as dust, water, and oil are removed from the compressed air. This ensures that downstream equipment remains protected and operates at its best. Regulation is the second phase, controlling the pressure of the compressed air in the system to match the requirements of the application. Lastly, lubrication introduces controlled amounts of oil into the flow of compressed air, reducing friction and increasing the lifespan of air-driven equipment.
Proper selection of the filter size, pressure rating, port size, and lubricator type is essential to meet the specific requirements of each application. By investing in high-quality compressed air preparation units, you can ensure the longevity of your pneumatic equipment and optimize its performance.
So, whether you are in manufacturing, automotive, or any other industry that relies on compressed air, understanding the importance of air preparation units is vital for efficient and reliable operation.
Importance of Air Preparation in Pneumatic Systems
Air preparation plays a vital role in pneumatic systems, ensuring the cleanliness, pressure, and lubrication of compressed air. In order to maintain optimal performance and reliability, it is crucial to address the presence of contaminants such as particles, water, and oil that can impair the operation of pneumatic components. Proper filtration is necessary to remove dirt, dust, and other particles from the compressed air and minimize the risk of damage to downstream equipment.
Moisture and oil, which can negatively impact the performance of pneumatic systems, are effectively eliminated through the use of coalescing filters. The level of air purity required will vary depending on the specific application, and different industry segments may have additional requirements to ensure the proper functioning of their equipment. Therefore, it is essential to select and implement the appropriate air preparation measures.
In addition to addressing contaminants, the flow rate of compressed air must be adequate to achieve the desired cylinder piston travel speeds. Furthermore, the operating pressure of the system needs to be carefully matched to the requirements of the application for optimal performance. By paying attention to these factors and implementing proper air preparation techniques, businesses can improve the process reliability, machine availability, and service life of their pneumatic components.
Tips for Designing and Specifying Air Preparation Systems
When designing or specifying air preparation subsystems, engineers need to consider several key factors to ensure optimal performance and minimize maintenance costs. One crucial aspect is properly matching the port sizes and operating pressure ranges of pneumatic components. This ensures efficient operation and prevents issues such as pressure drops or excessive pressure that can lead to equipment damage or downtime.
Another important consideration is the inclusion of disconnect components, such as manual shut-off relief valves and isolation/lockout valves. These components provide a means to isolate downstream equipment from the compressed air source, allowing for safe maintenance procedures and preventing inadvertent re-energization. This not only enhances safety but also reduces the risk of equipment breakdown and associated maintenance costs.
Air filtration is a critical aspect of air preparation systems, as it eliminates contaminants that could affect the performance and lifespan of pneumatic equipment. Various passive filters, such as centrifugal and coalescing filters, effectively remove particles, water, and oil from the compressed air, ensuring clean and reliable operation. Additionally, implementing appropriate drain systems, such as manual, semi-automatic, or automatic drains, helps to remove accumulated moisture from the filter bowl, further enhancing the efficiency and longevity of the system.
Finally, maintaining proper downstream air pressure is of utmost importance. This can be achieved through the installation of air pressure regulators. These regulators ensure that the compressed air delivered to the equipment operates at the correct pressure, preventing potential damage or inefficiencies caused by excessive or insufficient pressure. By following these tips and incorporating the right components, engineers can design and specify air preparation systems that optimize the performance and longevity of pneumatic equipment, ultimately reducing maintenance costs and downtime.
FAQ
What is an air preparation unit?
An air preparation unit, also known as an FRL unit (Filter, Regulator, Lubricator), is used to condition compressed air by removing contaminants, regulating pressure, and introducing controlled amounts of oil for lubrication.
Why is air preparation important in pneumatic systems?
Air preparation is essential in pneumatic systems to ensure the correct air cleanliness, pressure, and lubrication. Contaminants can impair the operation of components and reduce system reliability.
What does filtration do in an air preparation unit?
Filtration in an air preparation unit removes contaminants such as dust, water, and oil from the compressed air, ensuring cleaner air for downstream equipment.
How does regulation work in an air preparation unit?
Regulation in an air preparation unit controls the pressure of the compressed air in the system, allowing for precise pressure adjustments based on the requirements of the application.
Why is lubrication necessary in an air preparation unit?
Lubrication in an air preparation unit introduces controlled amounts of oil into the compressed air flow, reducing friction and increasing the lifespan of air-driven equipment.
What factors should I consider when designing or specifying air preparation subsystems?
When designing or specifying air preparation subsystems, consider proper port sizes and operating pressure ranges, disconnect components for isolation and lockout, air filtration for removing contaminants, drain systems for moisture removal, and air pressure regulators for maintaining proper downstream pressure.