Filters
Manufacturer
More in this category
Compressed Air Preparation Units
part#
description
manufacturer
538030
precision pressure regulator MS6N-LRP-1/4-D2-A8-Z indirectly controlled regulators, working pressure up to 0.7 bar, pressure outlet to front. Size: 6, Series: MS, Actuator lock: Rotary knob with lock, Assembly position: Any, Design structure: Piloted prec
customer-12
Quick Quote
541438
service unit combination MSB4N-1/4:J2M1D1A1-WP Comprising filter regulator, lubricator, electrical on-off valve, pneumatic soft-start valve, wall mounting plate Maximum output pressure 12 bar, 40 µm filter, with pressure gauge, lockable regulator head, pl
customer-12
Quick Quote
536544
electrical pressure regulator MS6N-LRE-1/2-D6-PU-Z Indirectly controlled regulators, working pressure up to 7 bar. Size: 6, Series: MS, Assembly position: (* Any, * Preferably vertical), Design structure: Electrically adjustable pressure regulator, Short
customer-12
Quick Quote
553058
fine filter MS9-LFM-N1-BUM-HF 1 µm filter, metal bowl guard, high flow rate, manual condensate drain, flow direction from left to right. Series: MS, Size: 9, Design structure: Fibre filter, Grade of filtration: 1 µm, Condensate drain: manual rotary
customer-12
Quick Quote
553078
micro filter MS9-LFM-3/4-AUM-DA 0.01 µm filter, metal bowl guard, manual condensate drain, with differential pressure indicator, flow direction from left to right. Series: MS, Size: 9, Design structure: Fibre filter, Grade of filtration: 0,01 µm, Condensa
customer-12
Quick Quote
186464
filter LF-1/2-D-5M-MAXI Degree of filtration 5 µm, with bowl guard and manual condensate drain. Size: Maxi, Series: D, Assembly position: Vertical +/- 5°, Grade of filtration: 5 µm, Condensate drain: manual rotary
customer-12
Quick Quote
186512
service unit FRC-1/2-D-7-MAXI-A Filter/regulator/lubricator combination, maximum outlet pressure 7 bar, 40 µm filter, with metal bowl guard. With automatic condensate drain. Size: Maxi, Series: D, Actuator lock: Rotary knob with lock, Assembly position:
customer-12
Quick Quote
542593
on-off valve MS6N-EE-1/2-10V24 Electrical, direction of flow: from left to right. Design structure: Piston slide, Type of actuation: electrical, Exhaust-air function: not throttleable, Manual override: Pushing, Type of reset: mechanical spring
customer-12
Quick Quote
186478
fine filter combination LFMBA-1/2-D-MAXI-A Micro filter 1 µm for prefiltration and micro filter 0.01 µm, with metal bowl guard. Size: Maxi, Series: D, Assembly position: Vertical +/- 5°, Grade of filtration: 0,01 µm, Filter efficiency: 99,9999 %
customer-12
Quick Quote
542310
service unit combination MSB4-1/4:C3J4-WP Comprising manual on-off valve, filter regulator, wall mounting plate. Maximum output pressure 12 bar, 5 µm filter, with pressure gauge, lockable regulator head, plastic bowl with plastic bowl guard, fully automat
customer-12
Quick Quote
543581
service unit combination MSB6N-1/2:C3J2M1D1A1F3-WP Comprising manual on-off valve, filter regulator, lubricator, electrical on-off valve, pneumatic soft-start valve, branching module with pressure switch without display, wall mounting plate. Maximum outpu
customer-12
Quick Quote
541291
on-off valve MS6N-EM1-1/2-S-Z Manual, with silencer, direction of flow: from right to left. Design structure: Rotary slide valve, Type of actuation: manual, Exhaust-air function: not throttleable, Type of piloting: direct, Valve function: 3/2 bistable
customer-12
Quick Quote
542274
service unit combination MSB6-1/2:C3J2-WP Comprising manual on-off valve, filter regulator, wall mounting plate. Maximum output pressure 12 bar, 40 µm filter, with pressure gauge, lockable regulator head, plastic bowl with plastic bowl guard, fully automa
customer-12
Quick Quote
546437
filter regulator LFR-D-MAXI With metal bowl guard. Size: Maxi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Grade of filtration: 40 µm
customer-12
Quick Quote
543595
service unit combination MSB6N-1/2:C3J4-WP Comprising manual on-off valve, filter regulator, wall mounting plate. Maximum output pressure 12 bar, 5 µm filter, with pressure gauge, lockable regulator head, plastic bowl with plastic bowl guard, fully automa
customer-12
Quick Quote
546470
filter regulator LFR-D-7-MAXI Output pressure max. 7 bar, without pressure gauge, 40 µ filtration grade. Size: Maxi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Vertical +/- 5°, Grade of filtration: 40 µm
customer-12
Quick Quote
542592
on-off valve MS6N-EE-1/4-10V24 Electrical, direction of flow: from left to right. Design structure: Piston slide, Type of actuation: electrical, Exhaust-air function: not throttleable, Manual override: Pushing, Type of reset: mechanical spring
customer-12
Quick Quote
186521
on-off valve HEL-1/4-D-MIDI Used in conjunction with service units for gradual pressure build-up. The valve function is equivalent to a 2/2-way valve. Exhaust-air function: throttleable, Type of actuation: pneumatic, Sealing principle: soft, Assembly posi
customer-12
Quick Quote
550500
service unit combination MSB6N-1/2:C3J1M1D7A1F3-WP Consisting of manual on-off valve, filter/regulator, oiler, electrical on-off valve, pneumatic soft-start valve, branching module with pressure switch but without display, wall mounting plate Maximum outp
customer-12
Quick Quote
192324
pressure regulator LR-3/4-D-O-I-MIDI With increased return exhaust, working pressure up to 12 bar. Size: Midi, Series: D, Actuator lock: Rotary knob with lock, Assembly position: Any, Design structure: directly-controlled diaphragm regulator
customer-12
Quick Quote
Items per page:
Compressed Air Preparation Units
General Guide & Overview
Compressed air is a widely used form of energy in various industries, powering pneumatic systems and equipment. However, the air leaving the compressor is often not suitable for direct use due to impurities and incorrect pressure levels. That's where air preparation units, also known as FRL units (Filter, Regulator, Lubricator), play a crucial role.
Air preparation units are designed to condition the compressed air, ensuring optimal performance and efficiency. The FRL unit consists of three separate units that carry out different phases of conditioning: filtration, regulation, and lubrication.
Filtration is the first step, where contaminants such as dust, water, and oil are removed from the compressed air. This ensures that downstream equipment remains protected and operates at its best. Regulation is the second phase, controlling the pressure of the compressed air in the system to match the requirements of the application. Lastly, lubrication introduces controlled amounts of oil into the flow of compressed air, reducing friction and increasing the lifespan of air-driven equipment.
Proper selection of the filter size, pressure rating, port size, and lubricator type is essential to meet the specific requirements of each application. By investing in high-quality compressed air preparation units, you can ensure the longevity of your pneumatic equipment and optimize its performance.
So, whether you are in manufacturing, automotive, or any other industry that relies on compressed air, understanding the importance of air preparation units is vital for efficient and reliable operation.
Importance of Air Preparation in Pneumatic Systems
Air preparation plays a vital role in pneumatic systems, ensuring the cleanliness, pressure, and lubrication of compressed air. In order to maintain optimal performance and reliability, it is crucial to address the presence of contaminants such as particles, water, and oil that can impair the operation of pneumatic components. Proper filtration is necessary to remove dirt, dust, and other particles from the compressed air and minimize the risk of damage to downstream equipment.
Moisture and oil, which can negatively impact the performance of pneumatic systems, are effectively eliminated through the use of coalescing filters. The level of air purity required will vary depending on the specific application, and different industry segments may have additional requirements to ensure the proper functioning of their equipment. Therefore, it is essential to select and implement the appropriate air preparation measures.
In addition to addressing contaminants, the flow rate of compressed air must be adequate to achieve the desired cylinder piston travel speeds. Furthermore, the operating pressure of the system needs to be carefully matched to the requirements of the application for optimal performance. By paying attention to these factors and implementing proper air preparation techniques, businesses can improve the process reliability, machine availability, and service life of their pneumatic components.
Tips for Designing and Specifying Air Preparation Systems
When designing or specifying air preparation subsystems, engineers need to consider several key factors to ensure optimal performance and minimize maintenance costs. One crucial aspect is properly matching the port sizes and operating pressure ranges of pneumatic components. This ensures efficient operation and prevents issues such as pressure drops or excessive pressure that can lead to equipment damage or downtime.
Another important consideration is the inclusion of disconnect components, such as manual shut-off relief valves and isolation/lockout valves. These components provide a means to isolate downstream equipment from the compressed air source, allowing for safe maintenance procedures and preventing inadvertent re-energization. This not only enhances safety but also reduces the risk of equipment breakdown and associated maintenance costs.
Air filtration is a critical aspect of air preparation systems, as it eliminates contaminants that could affect the performance and lifespan of pneumatic equipment. Various passive filters, such as centrifugal and coalescing filters, effectively remove particles, water, and oil from the compressed air, ensuring clean and reliable operation. Additionally, implementing appropriate drain systems, such as manual, semi-automatic, or automatic drains, helps to remove accumulated moisture from the filter bowl, further enhancing the efficiency and longevity of the system.
Finally, maintaining proper downstream air pressure is of utmost importance. This can be achieved through the installation of air pressure regulators. These regulators ensure that the compressed air delivered to the equipment operates at the correct pressure, preventing potential damage or inefficiencies caused by excessive or insufficient pressure. By following these tips and incorporating the right components, engineers can design and specify air preparation systems that optimize the performance and longevity of pneumatic equipment, ultimately reducing maintenance costs and downtime.
FAQ
What is an air preparation unit?
An air preparation unit, also known as an FRL unit (Filter, Regulator, Lubricator), is used to condition compressed air by removing contaminants, regulating pressure, and introducing controlled amounts of oil for lubrication.
Why is air preparation important in pneumatic systems?
Air preparation is essential in pneumatic systems to ensure the correct air cleanliness, pressure, and lubrication. Contaminants can impair the operation of components and reduce system reliability.
What does filtration do in an air preparation unit?
Filtration in an air preparation unit removes contaminants such as dust, water, and oil from the compressed air, ensuring cleaner air for downstream equipment.
How does regulation work in an air preparation unit?
Regulation in an air preparation unit controls the pressure of the compressed air in the system, allowing for precise pressure adjustments based on the requirements of the application.
Why is lubrication necessary in an air preparation unit?
Lubrication in an air preparation unit introduces controlled amounts of oil into the compressed air flow, reducing friction and increasing the lifespan of air-driven equipment.
What factors should I consider when designing or specifying air preparation subsystems?
When designing or specifying air preparation subsystems, consider proper port sizes and operating pressure ranges, disconnect components for isolation and lockout, air filtration for removing contaminants, drain systems for moisture removal, and air pressure regulators for maintaining proper downstream pressure.